Weld Overlay Process for Q345R and 0Cr18Ni12Mo2Ti Clad Plate
Overview and Background
The combination of Q345R (Chinese standard low-alloy steel for pressure vessels, equivalent to SA-516 Gr.70) and 0Cr18Ni12Mo2Ti (Chinese standard austenitic stainless steel, equivalent to 321) is one of the most common clad plate configurations in pressure vessel fabrication. This combination provides excellent economic efficiency: the carbon steel provides structural strength at low cost, while the stainless steel provides corrosion resistance for the internal service environment. The weld overlay process for joining clad plate sections involves critical considerations regarding dilution control, bond line integrity, and maintenance of the corrosion-resistant properties of the overlay layer.
Material Characteristics and Standards
| Property | Q345R (Carbon Steel) | 0Cr18Ni12Mo2Ti (SS Clad) |
|---|---|---|
| Yield strength | ≥345 MPa | ≥205 MPa |
| Tensile strength | 490-630 MPa | 520-750 MPa |
| Carbon content | ≤0.20% | ≤0.12% |
| Chromium | 0.30-0.60% | 17.0-19.0% |
| Nickel | 0.30-0.60% | 10.0-12.0% |
| Molybdenum | ≤0.30% | 2.0-3.0% |
| Titanium | ≤0.030% | 5×C to 0.70% |
| Applicable standard | GB/T 713 | GB/T 24511 |
| Clad plate standard | GB/T 19082 | EN 10028-7 |
Bond Line Requirements
According to GB/T 19082 and NB/T 47015, the clad plate must demonstrate:
- Minimum bond strength: 100% of the lower of the two base metals (i.e., ≥205 MPa for SS clad)
- No delamination under hydrostatic pressure test (typically 1.5× design pressure)
- Peel test: minimum 100 N/cm for 321/steel combination
- Hydrogen-induced cracking (HIC) resistance per NACE MR0175 for sour service
Weld Overlay Process Design
Process Selection Matrix
| Configuration | Recommended Process | Filler Metal | Key Consideration |
|---|---|---|---|
| SS-to-SS (clad face) | GTAW + GMAW | ER308L / ER347 | Maintain Ti stabilization |
| Steel-to-steel (base) | SAW + FCAW | E7018 / E8010-D1 | Full penetration |
| SS-to-steel (edge) | GTAW (root) + SAW (fill) | ER309L (root) | Dilution control |
| Clad-to-clad (edge) | GTAW only | ER347 | Minimum dilution |
Critical Welding Sequence for Clad Plate Vessels
- Base metal preparation: bevel edges showing both layers; mark clad thickness clearly
- Base metal welding: weld carbon steel layers using low-hydrogen process; grind flush to clad surface
- Clad layer restoration: deposit 2-3 passes of austenitic stainless steel to restore clad thickness
- Post-weld treatment: solution heat treatment at 1050°C for 1 hour (if required by design)
- Final inspection: UT bond test, PT of weld overlay, dimensional verification
Heat Input and Dilution Control
For the critical edge weld where clad layers are joined:
| Weld Position | Heat Input (kJ/mm) | Target Dilution | Acceptable Dilution |
|---|---|---|---|
| Root pass (GTAW) | 0.3-0.6 | <25% | <30% |
| Fill passes (GTAW) | 0.6-1.0 | <20% | <25% |
| Cap pass (GTAW) | 0.4-0.7 | <15% | <20% |
| Full weld (avg) | 0.5-0.8 | <20% | <25% |
Defect Analysis and Engineering Challenges
Typical Defects in Clad Plate Welding
| Defect | Location | Cause | Consequence | Detection |
|---|---|---|---|---|
| Cracking in HAZ | Steel side | High carbon equivalent, rapid cooling | Loss of strength | MT + UT |
| Intergranular corrosion | SS weld zone | Carbon migration, sensitization | Corrosion failure | Salt spray + metallography |
| Delamination | Bond line | Poor fusion, gas inclusion | Loss of containment | UT bond test |
| Excessive dilution | Clad weld | High heat input, wrong filler | Loss of corrosion resistance | Chemical analysis |
| Undercut | Clad surface | Poor technique | Stress concentration | Visual + PT |
Engineering Practice Case Study
In the fabrication of a hydrogenation reactor (design pressure 15 MPa, design temperature 420°C, sour service) using Q345R/0Cr18Ni12Mo2Ti clad plate:
- Challenge: The reactor required a 3.0 mm clad layer with 99.9% bond integrity and resistance to sulfide stress corrosion (SSC) per NACE MR0175
- Solution: Implemented a three-stage welding approach:
- Base metal: FCAW with E8010-D1, heat input 1.5-2.5 kJ/mm, preheat 100°C
- Transition: GTAW with ER309L, 2 passes, heat input 0.5 kJ/mm
- Clad restoration: GTAW with ER347, 3 passes, heat input 0.4-0.6 kJ/mm
- Results:
- Bond strength: 285 MPa (139% of minimum requirement)
- HIC test: 0% crack area (passes NACE MR0175)
- Corrosion rate: <0.05 mm/year in simulated sour environment
- Dilution in final pass: 12% (well below 25% limit)
Study Insights and Reflections
The welding of Q345R/0Cr18Ni12Mo2Ti clad plate is fundamentally a dilution management exercise. Every process parameter — from base metal preheat to final cap pass current — must be optimized to minimize iron contamination of the stainless steel overlay while maintaining adequate fusion and mechanical integrity. The most common failure mode in field service is intergranular corrosion caused by excessive dilution or sensitization during welding, which is why the use of stabilized fillers (ER347 with titanium) is strongly preferred over ER308L for critical applications.
Furthermore, the inspection strategy must be comprehensive: ultrasonic bond testing is non-negotiable for verifying the integrity of the steel-SS interface, while intergranular corrosion testing per ASTM A262 Practice A or E is essential for confirming the metallurgical quality of the weld overlay. Engineers should never accept a clad plate weld based solely on visual and penetrant inspection — the hidden failure modes at the bond line and within the sensitized zone are invisible to surface methods.